Set Telnet Parameters - Avaya S8300 Series Replacement Manual

Job aids for field replacements (frus) with the g700 media gateway
Hide thumbs Also See for S8300 Series:
Table of Contents

Advertisement

Job Aid: S8300 Communication Manager and co-resident SES: Replacing the S8300C or S8300D Server or
9. Hold the server on its side with the hard drive aligned with the mounting holes, and screw
the two screws through the bottom of the server into the hard-drive standoffs.
10. Guide the replacement server into the appropriate slot of the media gateway, but do not
completely insert it in the slot.
11. Before completely inserting the S8300C or S8300D Server into its slot in the media
gateway, connect the USB DVD-ROM/CD-R/W drive to the server.
12. Place the customer's Communication Manager CD in the USB DVD-ROM/CD-R/W reader
and close the tray.
13. Completely insert the S8300C or S8300D in its slot and secure by tightening the thumb
screws.
14. Power up the gateway if the power was removed earlier.

Set TELNET parameters

The Microsoft TELNET application might be set to send a carriage return (CR) and line
feed (LF) each time you press Enter. The installation program interprets this as two key
presses. You must change this before you TELNET to the server.
Note:
This procedure is performed entirely at your laptop, not on the server.
Note:
1. Click on Start > Run to open the Run dialog box.
2. Type telnet and press Enter to open a Microsoft TELNET session.
3. Type unset crlf and press Enter.
4. Type display and press Enter to confirm that either Sending only CR or Line feed
mode--causes the return key to send CR displays.
5. Type quit or close the TELNET window by clicking on the X in the upper-right corner.
This resets your Microsoft TELNET defaults and does not need to be done each time you
use TELNET.
26 Job Aids for Field Replacements (FRUs) for the Avaya S8300 Server with the G700 Media Gateway

Advertisement