Siemens Sinumerik 840D Series Function Manual page 195

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

02.99
10.03
300 754
Explanation
Response
Remedy
Continue program
300 770
Explanation
Response
Remedy
Continue program
300 799
Explanation
 Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Axis %1, drive %2 signal number var. signaling function invalid
%1 = NC axis number
%2 = drive number
The signal number for output of the appropriate signaling function is illegal. The
permissible signal number range starts at 0 and ends at 29.
NC not ready.
Under certain circumstances it can be switched over across the entire channel
via MD.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
Please inform the authorized personnel/service department.
Enter the correct signal number.
Clear alarm on all channels by pressing RESET. Restart part program.
Axis %1, drive %2 format error
%1 = NC axis number
%2 = drive number
The calculated filter coefficients of a bandstop filter are beyond the range of the
internal format.
The alarm can be reconfigured using MD 11412:
ALARM_REACTION_CHAN_NOREADY (channel not ready).
NC not ready.
Under certain circumstances it can be switched over across the entire channel
via MD.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
Please inform the authorized personnel/service department. Change the filter
setting. The hotline can help you to trace the exact cause of the fault. Call the
SIEMENS AG, SIMODRIVE Hotline.
Cancel alarm in all channels by pressing RESET. Restart part program.
Axis %1, drive %2 save and boot necessary
%1 = NC axis number
%2 = drive number
After drive machine data have been modified, parameters need to be re-calcu-
lated. Press the CALCULATE soft key to start the calculation routine. After cal-
culating the control parameters, it is necessary to save the machine data and to
reboot.
The alarm can be reconfigured using MD 11412:
ALARM_REACTION_CHAN_NOREADY (channel not ready).
6 Hydraulics Diagnostics
6-195