4 Firmware Drive Functions
4.14 Service functions
Software version
5797
PBL_VERSION
Data version
Unit:
Default:
-
0
5798
FIRMWARE_DATE
Firmware date
Unit:
Default:
-
0
5799
FIRMWARE_VERSION
Firmware version
Unit:
Default:
-
0
4-164
If the force controller (force limitation or friction injection) has been activated in
MD 5241, the effective force setpoint is displayed here. This can be specified
by:
S
the force limitation (MD 5230 or 5231)
S
the friction injection (MD 5234 or MD 5235)
S
the NC via the "Travel to fixed stop" function
It must be noted that the force controller is activated only in conjunction with
friction injection and zero speed or with force limitation and violation of the upper
force limit. The voltage setpoint of the velocity controller is otherwise applied, in
which case the force setpoint is irrelevant.
Minimum:
Maximum:
0
FFFF
Output of current data version (machine data list).
Minimum:
Maximum:
0
FFFF
Output of coded software release. The display is decimal. The character string
has the following format:
DDMMY, in which DD stands for day, MM for month and Y = last digit of year.
Example:
The code for 01.06.1993 is 1063
Minimum:
Maximum:
0
FFFFFF
Output of current software release. The display is decimal, e.g. 21000. This is
the code for SW version 2.10/00.
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
dec
Cross reference: -
Related to:
Protection level:
HLA
Data type:
Active:
UNS.DWORD
Read-only
Siemens AG, 2003. All rights reserved
10.03