3 Startup

3.7 Measuring system data

3.7
Measuring system data
Softkey "Ready"
Activation of data
3-58
Fig. 3-11
"Measuring System Data HLA, Incremental" menu display
To set the encoder parameters, select either the "Incremental" or the "Absolute
(EnDat interface/SSI interface)" option.
The value of the associated machine data is displayed as the scale graduation.
You can return to menu display "Mounting/supply data for HLA" by selecting
softkey "Back".
Select the "Ready" softkey to conclude the start-up for this drive.
A dialog message then appears. This must be acknowledged with "Abort" or
"OK".
Fig. 3-12
Dialog message "Start-up ready"
You can return to menu display "Measuring system data for HLA" by selecting
softkey "Abort".
Press "OK", to write the machine data to the drive. The drive model and control-
ler data are then calculated and the boot file saved. The program then jumps to
the "Valve/Controller..." menu display (see Fig. 3-5), where data can be checked
and/or modified using "Change valve data".
The remaining drives can then be started up.
The entered/calculated data can be activated by an NCK power On/Reset.