Stator Checking - LinMot P10-54 Installation Manual

Linear motors
Hide thumbs Also See for P10-54:
Table of Contents

Advertisement

Installation Guide Linear Motors

6.2 Stator checking

The following tables show the resistive value between the different connector pins for each stator type. If the
value is not within a range of +/- 10% the stator may be damaged (temperature of the stator for all
measurements: 25°C).
PS10-54x120U-BL-TU
PS10-54x120U-BL-TU-D24
Phase U / Phase V
Phase V / Phase W
Phase W / Phase U
Casing
Pt1000+ / Pt1000-
(only series D24)
PTC+ / PTC-
(only series D25 / D25S)
PS10-54x180U-BL-TU
PS10-54x180U-BL-TU-D24
Phase U / Phase V
Phase V / Phase W
Phase W / Phase U
Casing
Pt1000+ / Pt1000-
(only series D24)
PTC+ / PTC-
(only series D25 / D25S)
PS10-54x240U-BL-TU
PS10-54x240U-BL-TU-D24
Phase U / Phase V
Phase V / Phase W
Phase W / Phase U
Casing
Pt1000+ / Pt1000-
(only series D24)
PTC+ / PTC-
(only series D25 / D25S)
PS10-54x300U-BL-TU
PS10-54x300U-BL-TU-D24
Phase U / Phase V
Phase V / Phase W
Phase W / Phase U
Casing
Pt1000+ / Pt1000-
(only series D24)
PTC+ / PTC-
(only series D25 / D25S)
* Temperature resistances can only be correctly set with active sensor power supply.
(emulated temperature resistance).
NTI AG / LinMot
(0150-2722)
PS10-54x120U-BL-TU-D25
(0150-2748)
PS10-54x120U-BL-TU-D25S
Pin A / Pin B
Pin B / Pin C
Pin C / Pin A
Any phases / Casing
Pin 1 / Pin 2
Pin 1 / Pin 2
(0150-2723)
PS10-54x180U-BL-TU-D25
(0150-2749)
PS10-54x180U-BL-TU-D25S
Pin A / Pin B
Pin B / Pin C
Pin C / Pin A
Any phases / Casing
Pin 1 / Pin 2
Pin 1 / Pin 2
(0150-2724)
PS10-54x240U-BL-TU-D25
(0150-2750)
PS10-54x240U-BL-TU-D25S
Pin A / Pin B
Pin B / Pin C
Pin C / Pin A
Any phases / Casing
Pin 1 / Pin 2
Pin 1 / Pin 2
(0150-2725)
PS10-54x300U-BL-TU-D25
(0150-2751)
PS10-54x300U-BL-TU-D25S
Pin A / Pin B
Pin B / Pin C
Pin C / Pin A
Any phases / Casing
Pin 1 / Pin 2
Pin 1 / Pin 2
P10-54 / P10-54-D24/25/25S
ENG
(0150-2752)
(0150-2782)
14  @ 25 °C
14  @ 25 °C
14  @ 25 °C
> 200 M @ 25 °C
20 ± 0.2 k @ 25 °C
20 ± 0.2 k @ 25 °C
(0150-2753)
(0150-2783)
5.7  @ 25 °C
5.7  @ 25 °C
5.7  @ 25 °C
> 200 M @ 25 °C
20 ± 0.2 k @ 25 °C
20 ± 0.2 k @ 25 °C
(0150-2754)
(0150-2784)
7.5  @ 25 °C
7.5  @ 25 °C
7.5  @ 25 °C
> 200 M @ 25 °C
20 ± 0.2 k @ 25 °C
20 ± 0.2 k @ 25 °C
(0150-2755)
(0150-2785)
5.7  @ 25 °C
5.7  @ 25 °C
5.7  @ 25 °C
> 200 M @ 25 °C
20 ± 0.2 k @ 25 °C
20 ± 0.2 k @ 25 °C
Page 25 / 32

Advertisement

Table of Contents
loading

This manual is also suitable for:

P10-54-d25P10-54-d24P10-54-d25s

Table of Contents