PTP EXPERNAL CLOCK MODE

Configuration
PTP
This page allows the user to configure and inspect the current PTP clock settings.

PTP EXTERNAL CLOCK CONFIGURATION

One_PPS_Mode
This Selection box will allow you to select the One_pps_mode configuration.
The following values are possible:
1. Output: Enable the 1 pps clock output
2. Input: Enable the 1 pps clock input
3. Disable: Disable the 1 pps clock in/out-put
External Enable
This Selection box will allow you to configure the External Clock output.
The following values are possible:
1. True: Enable the external clock output
2. False: Disable the external clock output
Adjust Method
This Selection box will allow you to configure the Frequency adjustment configuration.
1. LTC frequency: Select Local Time Counter (LTC) frequency control
2. SyncE-DPLL: Select SyncE DPLL frequency control, if allowed by SyncE
3. Oscillator: Select an oscillator independent of SyncE for frequency control, if supported by the
HW
4. LTC phase: Select Local Time Counter (LTC) phase control (assumes that the frequency is
locked by means of SyncE)
PAGE 214
OPTICAL SYSTEMS DESIGN
OSD2790SFP OPERATOR MANUAL