5.8.4

Technical data

Memory configuration
Storage technology
Memory organization
Protocol
Data retention (at +25 °C)
MTBF (at +25 °C)
Read/write distance (Sg)
Recommended distance to metal
Multitag capability
Power supply
Degree of protection according to EN 60529
Vibration
Torsion and bending load
Mechanical design
Mounting
Ambient temperature
Weight
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
Serial number
Application memory
Read cycles
Write cycles, min.
Write cycles, typical
Color
Material
Dimensions (L x W x H in mm)
Operation
Transport and storage
8 bytes (fixed code)
256 bytes
EEPROM
4 bytes, block by block
according to ISO 15693
10 years
2 x 105 hours
Unlimited
100 000
1 000 000
See Chapter Field data (Page 33)
25 mm (approx. 30% reduction of the field data)
Yes
Inductive power transmission (without battery)
IP67
ISO 10373/ISO 7810
ISO 10373/ISO 7816-1
Laminated plastic card, printable on both sides
White
PET
85 x 54 x 0.8
Adhesive, fixing lug
-20 °C to +60 °C
-20 °C to +60 °C
approx. 5 g