Error Messages And Causes For Moby D In Combination With The Mdwapi Library - Siemens SIMATIC MOBY D System Manual

Rfid systems
Table of Contents

Advertisement

Alarm, error and system messages

11.1 Error messages and causes for MOBY D in combination with the MDWAPI library

11.1
Error messages and causes for MOBY D in combination with the
MDWAPI library
Table 11- 1
Error code
in HEX
0x00
Table 11- 2
Error code
in HEX
0x01
0x02
0x03
0x04
0x05
0x06
280
General errors
Cause, remedy
OK:
Data/parameters read or saved without errors
Control command executed
Transponder status
Cause, remedy
No transponder:
No transponder within the detection field of the reader
Transponder in detection field has been switched to silent
Error in communication between reader and transponder. The reader can no longer
detect the transponder.
Invalid data:
CRC16 checksum error in the received data
Write error:
Plausibility test of written data failed:
Attempt to write to a read-only area
Distance between transponder and read antenna too large
Attempt to write during excessive ambient noise
Address error:
The requested data lie beyond the logical or physical address range of the transponder:
The addresses lie outside the maximum address range of the transponder
The addresses lie outside the configured address range of the transponder
Invalid transponder type:
This command is not supported by this transponder:
Write or read attempt with a transponder
A specific command is not supported by the transponder.
Read error:
Plausibility test of read data failed:
Distance between transponder and read antenna too large
Attempt to read during excessive ambient noise
System Manual, 01/2010, J31069-D0147-A6-7618