Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents English Overview ..............................4 General ................................ 4 Delivery contents ............................4 Power supply ............................... 4 Layout and connections ..........................5 Dimensions ..............................5 Connections and displays ........................... 6 2.2.1 Possible states of the LEDs ........................6 Pin allocation ............................... 7 2.3.1 P1 - Power, Digital output - plug-in connector ....................
1 Overview 1.1 General The transponder SIMATIC RTLS4460T represents the movable device considered for localization within the SIMATIC Locating Manager localization network. It sends its positional information to the localization network’s nodes (anchors and gateways) which transmit the data to the localization server for computation and visualization. The device is suitable for installation into vehicles and devices 1.2 Delivery contents 1 SIMATIC RTLS4460T (article number 6GT2700-6CE02)
2.2 Connections and displays Connection Description P1 - Power, Digital Power supply and digital input signals P3 - Antenna RP-SMA - Antenna screw connector Fuse Mini blade fuse, 2 A Display Description LED signaling the activity of the Locating Manager (sending D1 - Radio LED (yellow) and receiving radio signals) D2 - Run LED (green)
2.3 Pin allocation 2.3.1 P1 - Power, Digital output - plug-in connector 16-pin plug-in connector WR-MPC4 0.33 mm² by 1.31 mm² Description Description n.c. n.c. Digital input 7 Digital input 8* Digital input 5 Digital input 6 Digital input 3 Digital input 4 Digital input 1 Digital input 2...
2.3.2 Digital output Both of the device digital outputs can drive ohmic, capacitive and inductive loads. The current will be limited automatically at this. In case of inductive loads (e.g. relays) consider the following: Inductivities up to 32 H can be turned off without flyback diode D .
3 Installation, initial start-up, safety 3.1 General information The devices can only be used in combination with the Locating Manager. • Buildup, installation as well as the use of the tools and clients of the localization system are • described in the corresponding guides and manuals. 3.2 Installation and operation Carefully read all items listed in section 3 (Installation, initial start-up, safety) before installing •...
4 Technical data 4.1 Connectors and power supply Connectors and power supply Voltage 24 V DC Power consumption Max. 1.6 W /0.06 A Power connector (P1) 16-pin plug-in connector WR-MPC4, 0.33 mm² by 1.31mm² Antenna connector RP-SMA connector Fuse Mini blade fuse, 2 A 4.2 In- and outputs In- and outputs Input voltage...
4.4 Environment Environment and dimensions Case Plastic housing IP-protection IP 20 Dimension 138 x 62 x 31 mm Weight 125 g Mounting 4 mounting holes for M4 countersunk head screw Temperature range -40 … + 70 °C SIMATIC RTLS4460T Device manual, 06/2019, C79000-G8976-C522-02...
5.1 EU declaration of conformity You can find the current EU declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14970/cert) The products described in this document meet the requirements of the following EC directives: RoHS directive 2011/65/EU •...
5.3 RED 5.3.1 Protection of health and safety The products described in this document meet the requirements of the applied standards: Article 3 (1) a) protection of health and safety • EN 62368-1 Information technology equipment - Safety - Part 1: General requirements •...
Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations.
Need help?
Do you have a question about the SIMATIC RTLS and is the answer not in the manual?
Questions and answers