Planning the MOBY D system
4.3 Installation guidelines
SLG D10/D10S with ANT D10
Table 4- 19
MDS D100
MDS D124
MDS D139
MDS D160
MDS D324
MDS D424
MDS D428
MDS D460
MDS D200
1)
Note
The values specified in the tables must be complied with. The inductive fields may be
affected if the distance is smaller. In this case, the data transfer time would increase
unpredictably or a command would be aborted with an error.
If the distance is smaller, it is recommended that a test is performed.
48
Reduction of field data by metal (in %): MDS and SLG D10/D10S with ANT D10
Transponder
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
distance all-round 20 mm
Without metal
On metal, distance 25 mm
Flush-mounted in metal;
distance all-round 25 mm
Without metal
On metal, distance 30 mm
Without metal
1)
On metal; distance 25 mm
Flush-mounted in metal;
distance all-round 25 mm
Without metal
On metal; distance 25 mm
Flush-mounted in metal;
distance all-round 25 mm
Without metal
On metal; distance 25 mm
Flush-mounted in metal;
distance all-round 25 mm
Without metal
On metal
Without metal
On metal; distance 25 mm
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
distance all-round 20 mm
Values apply to metal surfaces greater than 100 mm x 100 mm
SLG D10/D10S with ANT D10
On metal
Flush-mounted in metal
(200 mm all-round)
100
50
--
100
70
--
100
80
100
65
--
100
70
--
100
70
--
100
50
100
50
100
50
--
System Manual, 01/2010, J31069-D0147-A6-7618
90
40
--
90
60
--
90
70
90
55
--
90
60
--
90
60
--
90
40
90
40
90
40
--
MOBY D