Technical Data - Siemens SIMATIC MOBY D System Manual

Rfid systems
Table of Contents

Advertisement

Mobile data storage units
5.3 MDS D100
5.3.5

Technical data

Table 5- 4
Memory size
Memory configuration
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles, typical
Write cycles, min.
Read/write distance (S
Distance from metal
Multitag capability
Power supply
Degree of protection to EN 60529
Vibration
Torsion and bending load
Mechanical design
Fixing
Ambient temperature
Weight, approx.
104
Technical data for MDS D100
Serial number
Configuration memory
Application memory
)
g
Color
Material
Dimensions (L x W x H) in mm
During operation
Transport and storage
128 bytes
8 bytes (fixed code)
8 bytes
112 bytes
EEPROM
EEPROM 128 bytes gross
112 bytes net capacity
When using the OPT area, 16 bytes of it must be
subtracted in 4 byte blocks
according to ISO 15693
10 years
2 x 10
hours
6
Unlimited
1 000 000
100 000
See Chapter .
min. 20 mm (approx. 30% reduction of the field data)
Yes
Inductive power transmission (without battery)
IP68
ISO 10373/ISO 7810
ISO 10373/ISO 7816-1
Laminated plastic card, printable on both sides
White/petrol
PC
85.6 (±0.2) x 54 (±0.2) x 0.9 (±0.05)
Adhesive, fixing pocket
-25 °C to +80 °C
-25 °C to +80 °C
5 g
System Manual, 01/2010, J31069-D0147-A6-7618
MOBY D

Hide quick links:

Advertisement

Table of Contents
loading