Write/read devices with RS232 interface
6.3 SLG D11 basic unit
6.3.3

Technical specifications

Table 6- 8
Inductive interface to the MDS
Transmission frequency
Transponders supported
Serial interface to the user
Transmission protocol
Data transmission rate
Data backup
Transmit power
Write/read distances
SLG - MDS
Software functions
Programming
Multitag
Anti-collision speed
Power supply
Current consumption
Cable length, SLG - PC
Digital inputs/outputs
Dimensions (L x W x H) in mm
Color
Material
Connectors
SLG fixing
Tightening torque
(at room temperature)
Ambient temperature
MTBF
Degree of protection to EN 60529
158
Technical data of SLG D11
Rated value
Permitted range
Operation
Inrush current, momentary
With RS 232
Antenna (plugs into SLG)
V24 interface
Power supply
Operation
Transport and storage
13.56 MHz
Transponders to ISO 15693 and I-Code1
RS 232
Asynchronous 8 bit
9600 baud to 38.4 Kbaud (adjustable)
CRC 16
1 W
See
Read, write, initialize MDS, access rights
Windows 9x, 2000, NT and XP,
with 32 bit DLL available
Yes
approx. 20 labels/s simultaneously identifiable
200 mA
600 mA
Max. 30 m
None
160 x 80 x 40 without connector
Anthracite
Plastic PA 12
TNC connector
9-pin Sub-D connector (male)
4-pin M12 connector (male)
2 x M5 screws
≤ 2 Nm
-25 °C to +55 °C
-25 °C to +70 °C
2.0 x 10
hours
5
IP65 (UL: for indoor only)