Technical Specifications - Siemens SIMATIC MOBY D System Manual

Rfid systems
Table of Contents

Advertisement

Write/read devices with RS422 interface
7.5 SLG D12S (plug-in version)
7.5.3

Technical specifications

Table 7- 13
Inductive interface to the MDS
Transmission frequency
Transponders supported
Serial interface to the user
Transmission protocol
Data transmission rate
Data backup
Transmit power
Write/read distances SLG - MDS
Software functions
Programming
Transmission protocol
Multitag
Power supply
Current consumption
Cable length SLG – SIMATIC S7
Digital inputs/outputs
Dimensions (L x W x H) in mm
Connector
Mounting
Ambient temperature
MTBF
Degree of protection to EN 60529
Shock resistant to EN 60721-3-7, Class 7M2
Total shock response spectrum, Type II
Vibration compliant with EN 60721-3-7, Class
7M2
196
Technical specifications for SLG D12S special version
Operation
Inrush current, momentary
With RS 422
Color
Material
RS-422 interface/power supply
Operation
Transport and storage
13.56 MHz
Transponders to ISO 15693 and I-Code1
RS 422
Asynchronous 8 bit
19.2 Kbaud
CRC 16
1 W (reset parameter 04 hex)
160 mm typically (see field data)
Read, write and initialize MDS
Concatenated commands are not permitted.
The Repeat command is not implemented.
The largest possible useful data length in a
command is 233 bytes.
FB/FC 45
3964R
no
Via ASM
150 mA
600 mA
300 m
None
160 x 80 x 40 (without connector)
Anthracite
Plastic PA 12
8-pin M12 connector (male)
2 x M5 screws
-25 °C to +55 °C
-25 °C to +70 °C
2.0 x 10
hours
5
IP67
30 g
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
System Manual, 01/2010, J31069-D0147-A6-7618
MOBY D

Hide quick links:

Advertisement