Installation Guidelines; Overview; Permissible Mounting Material - Siemens SIMATIC MOBY D System Manual

Rfid systems
Table of Contents

Advertisement

Planning the MOBY D system

4.3 Installation guidelines

4.3
Installation guidelines
4.3.1

Overview

The MDS and SLG are inductive devices. Any type of metal, in particular iron and
ferromagnetic materials, in the vicinity of these devices will affect their operation. Some
points need to be considered during planning and installation if the field data described in the
preceding chapter are to retain their validity:
● The use of permissible mounting material
● The minimum distance between two antennas
● The minimum distance between two adjacent MDS
● The metal-free area for flush-mounting of SLGs in metal
● Mounting of multiple antennas on metal frames or racks
The following sections describe the impact on the functionality of the MOBY D identification
system when mounted in the vicinity of metal.
4.3.2

Permissible mounting material

Securing SLG and antennas
In order to comply with UL guidelines, the components must only be secured with the fixing
materials described below.
The positions of the fixing holes for the device are shown in the
Fixing to metal
Table 4- 13
SLG/antenna
SLG D11, SLG D11S;
SLG D12, SLG D12S;
Antenna duplexer
SLG D10, SLG D10S
Antenna ANT D5
ANT D6 antenna
ANT D10 antenna
1)
38
(see chapter "Antennas (Page 205)")
(see chapter "Mobile data storage units (Page 95)")
Fixing the SLG and antennas to metal
Represents minimum length
Dimension drawings
Screw type
1
M5 x 8, 8.8, DIN ISO 4017
M6 x 8, 8.8, DIN ISO 4017
M6 x 8, 8.8, DIN ISO 4017
M6 x 8, 8.8, DIN ISO 4017
M6 x 8, 8.8, DIN ISO 4017
System Manual, 01/2010, J31069-D0147-A6-7618
section.