Technical Specifications - Siemens SIMATIC MOBY D System Manual

Rfid systems
Table of Contents

Advertisement

Mobile data storage units
5.13 MDS D460
5.13.4

Technical specifications

Memory size
Memory configuration
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Bulk detection/multitag capability
Read cycles
Write cycles (at +40 °C, typical)
Read/write distance (S
Distance from metal
Power supply
Degree of protection to EN 60529
Shock, tested in accordance with IEC 68-2-27
Vibration, tested in accordance with IEC 68-2-6
Torsion and bending load
Enclosure
MDS fixing
Ambient temperature
Weight, approx.
1)
2)
146
Serial number
Configuration memory
Application memory
)
g
Color
Material
Dimensions (D x H) in mm
During operation
Transport and storage
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
The values for shock and vibration are maximum values and must not be applied continuously.
2048 bytes
8 bytes (fixed code)
40 bytes
2000 bytes
FRAM
2048 bytes gross
2000 bytes net
ISO 15693
10 years
2 x 10
hours
6
Yes
Unlimited
> 10
10
See Chapter Field data (Page 33)
Min. 15 mm (ca. 20% reduction of the field data)
Inductive power transmission
(without battery)
IP67
IPx9K
1)
50 g
2)
20 g
2)
Not permissible
Black
Epoxy casting resin
16(±0.2) x 3,0(±0.2)
Adhesion, spacer
-25 °C to +85 °C permanent
-40 °C to +100 °C
3 g
System Manual, 01/2010, J31069-D0147-A6-7618
MOBY D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents