Technical data
Table C- 17
Inductive interface to the MDS
Transmission frequency
Transponders supported
Serial interface to the user
Transmission protocol
Data transmission rate
Data backup
Transmit power
Write/read distances SLG - MDS
Software functions
Programming
Transmission protocol
Multitag
Power supply
Current consumption
Cable length SLG – SIMATIC S7
Antenna cable length
Digital inputs/outputs
Dimensions (L x W x H) in mm
Color
Material
Connectors
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
Technical data for SLG D11S ANT D5
Operation
Permitted range
Operation
Inrush current, momentary
With RS 422
For antenna
For the electronics
Antenna
SLG housing
Antenna
SLG housing
Antenna (plugs into SLG)
RS-422 interface
Power Supply
C.2 Discontinued SLG with ANT D5
13.56 MHz
Transponders to ISO 15693 and I-Code1
RS 422
Asynchronous 8 bit
19.2 Kbaud
CRC 16
1 W (reset parameter 04 hex)
380 mm typically (see field data)
Read, write and initialize MDS
Concatenated commands are not permitted.
The Repeat command is not implemented.
The largest possible useful data length in a command is 233
bytes.
FC 45
3964R
no
150 mA
600 mA
300 m
3.60 m (included in scope of supply)
None
340 x 325 x 38
160 x 80 x 40 without connector
Black
Anthracite
Plastic ASA
Plastic PA 12
TNC connector
9-pin Sub-D connector (male)
4-pin M12 connector (male)