Unipulse F600AT Operation Manual page 57

Weighing controller
Table of Contents

Advertisement

14.RS-232C INTERFACE
-
Status read (7-digit)
Host
F600AT
-
Status read (7-digit)
Host
F600AT
Weight error
No Weight error
In equivalent input calibration
In span calibration
In zero calibration
In weighing
-
Parameter read (example: High limit)
Host
F600AT
-
Parameter write (example: High limit)
Host
F600AT
Command No.
* When you write in a setup which it is not with the sign, put "0" in the sign digit.
* Please refer to "21 SETTING ITEM LIST" on page 65 for command No. and the number of
set digits.
- Parameter code read
Host
F600AT
-
Parameter code write
Host
F600AT
48
R
F
CR
R
F
Near zero
1: ON
0: OFF
LO-LO limit
1: ON
0: OFF
LO limit
1: ON
0: OFF
R
G
CR
R
G
: 1
: 0
: 4
: 3
: 2
: 1
W
0
2
CR
W
Command No.
Parameter No.
Sign
W
0
2
±
1
0
5-digit parameter (no decimal point)
W
0
0
CR
W
W
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Sign
0
2
±
1
0
0
5-digit parameter (no decimal point)
0
0
0
CR
0
0
0
0
0
0
0
0
CR
Parameter code 0 to 7
0
Terminator
HI-HI limit
1: ON
0: OFF
HI limit
1: ON
0: OFF
Proper weight
1: ON
0: OFF
0
Terminator
Sequence error
(0 to 5)
+LOAD occurred
: 5
-LOAD occurred
: 4
GROSS OVER occurred
: 3
NET OVER occurred
: 1
No error
: 0
0
0
Terminator
0
Terminator
Parameter code 0 to 7

Hide quick links: