11.TIMING CHART
11.TIMING CHART

11-1. Feed Weighing (In The Simple Comparison Mode)

NET
FINAL
FINAL – CPS
FINAL – SP2
FINAL – SP1
NEAR ZERO
0
NZ output
SP1 output
SP2 output
SP3 output
Comparison
inhibiting time
Judging time
STAB output
END output
OVER output
UNDER output
The overweight/underweight comparison timing depends on the OVER/UNDER COMP. setting under
COMPARISON. (It is set at "REGULARLY" in the illustration.)
The END signal output timing depends on the COMPLETE SIG.OUT setting under COMPARISON.
Conditional expression
-
NZ output
-
SP1 output
-
SP2 output
-
SP3 output
- UNDER
output
- OVER
output
Select the weight value for near zero comparison from GROSS or NET under COMPARISON setting
menu.
38
OFF
ON
ON
t1
t1
ON when the weight value ≦ preset near zero value
ON when the net ≧ preset final weight value – preset SP1 value
ON when the net ≧ preset final weight value – preset SP2 value
ON when the net ≧ preset final weight value – preset CPS value
ON when the net < preset final weight value – preset underweight value
ON when the net > preset final weight value + preset overweight value
OVER
UNDER
ON
ON
t2
ON
ON
t3
OFF
Time
t1: Comparison inhibiting time
COMP.INH.TIME under
COMPARISON
t2: Judging time
JUDGING TIME under
COMPARISON
t3: Completion output time
COMPLETE OUT T. under
COMPARISON