5. COMPARISON SETTING

■ Comparison mode setting

Select the comparison mode.
Alternatives:
Explanation of each alternative
HI/LO limit comparison (HI - LO COMP)
The net or gross weight is compared with the set values.
Final discharge – overweight/underweight comparison (DIS. - O/U)
This function is for accurate discharge of the weight value. Overweight/underweight judgment
is made by comparing with the net weight.
Final discharge – HI/LO limit comparison (DIS. - H/L)
This function is for accurate discharge of the weight value. Comparisons are made with the net weight.
High/low limit comparisons are made with the net or gross weight.

■ Comparison inhibiting time/ Judging time/ Completion output time

Valid in the discharge mode. Comparisons are not made for a fixed time by this function to prevent
inappropriate operation of control and judgment due to mechanical vibrations related to opening and
closing of valves. The length of the completion signal to be output when weighing is completed can
also be set.
COMP.INH.TIME
JUDGING TIME
COMPLETE OUT T. Setting range: 0.00 to 9.99 (sec.)
FINAL – CPS
FINAL – SP2
FINAL – SP1
[HI - LO COMP] [DIS. - O/U] [DIS. - H/L]
Setting range: 0.00 to 9.99 (sec.)
Setting range: 0.00 to 9.99 (sec.)
Comparison inhibiting timer
0
5.COMPARISON SETTING
Judging timer
21