Unipulse F600AT Operation Manual page 32

Weighing controller
Table of Contents

Advertisement

Example)
Final
Auto Free Fall Compensation Regulation
Average count of AFFC.
CPS coefficient
Times
Actual Weighing
0
1
20.050
2
20.040
3
20.070
4
20.080
5
20.020
6
20.000
7
20.010
8
20.110
9
20.010
10
19.880
11
19.990
12
20.010
13
20.000
14
19.980
Setting CPS coefficient
CPS coefficient can be selected from 1/4, 2/4, 3/4, or 1.
You can get more accurate CPS value by selecting 1 when each weight value is
approximate same in each measuring or by selecting 1/4 to 2/4 when each
weight value fluctuates in each measuring.
Error
Average count of AFFC.
0
+0.050
1
+0.040
2
+0.070
3
+0.080
4 → 0
+0.240/4 = 0.060
0.060×2/4 = 0.030
+0.020
1
0.000
2
+0.010
3
(+0.110)
← ×3
+0.010
4 → 0
+0.040/4 = 0.010
0.010×2/4 = 0.005
(-0.120)
← ×1
-0.010
1
+0.010
2
0.000
3
0.020
4 → 0
-0.020/4 = -0.005
-0.005×2/4 = 0.003
5.COMPARISON SETTING
20.000
0.100
4
2/4
CPS
← Power ON
0.500
0.500
0.500
0.500
→ CPS Value
0.530
0.530
0.530
0.530
0.530
→ CPS Value
0.535
0.535
0.535
0.535
0.535
→ CPS Value
0.532