To inspect
If any part is worn enough to have an effect on the performance of the oil pump, the complete oil pump must
be renewed.
1 Release the three Allen screws and remove the cover of the oil pump.
2 Remove the outer rotor and clean thoroughly all the parts. Check for cracks and any other damage.
3 Fit the outer rotor and check the outer rotor to body clearance with a feeler gauge (A).
4 Check the inner rotor to outer rotor clearance (B).
A
5 Check the rotor end-float with a straight edge and a feeler gauge (C). For all the above clearances, refer to
the relevant Data and dimensions for the "Lubrication system" on page 24.
6 Clean the top face of the oil pump and the bottom face of the cover and fit the cover.