2
900 Series
Maximum taper and out of round for journals and crankpins
Taper.. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0,009 mm (0.00035 in)
Out of round ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0,010 mm (0.00039 in)
Maximum run-out with crankshaft mounted on end journals:
Crankshaft pulley diameter (total indicator reading) .. ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0,025 mm (0.001 in)
Rear oil seal diameter (total indicator reading) .. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0,025 mm (0.001 in)
Flywheel flange diameter (total indicator reading) ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0,025 mm (0.001 in)
Run-out
With the crankshaft on mountings at the front and rear journals, the maximum run-out (total indicator reading)
at the journals must not be more than shown below:
A1... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... . Mounting
A2... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0,5 mm (0.002 in)
A3... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0,5 mm (0.002 in)
A4... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... . Mounting
F
D
C
C
E
B
R2
R2
R2
A
1
A
2
A
3
A
4
B
B
R1
R1
R1
R1
D
D
A
C0068
20
Workshop Manual, TPD 1345E, issue 3
This document has been printed from SPI². Not for Resale