Replace rim and glass.
3 3 ) )
2 2 . . 1 1 7 7 . . 7 7 . . 2 2 C C l l e e a a n n i i n n g g S S t t e e p p s s
Remove gauge and check inside the pipe fittings from deadweight body. Make
1 1 ) )
certain fittings are clean and open.
Clean and reinstall gauge.
2 2 ) )
2 2 . . 1 1 7 7 . . 8 8 C C o o n n d d e e n n s s a a t t i i o o n n B B o o x x A A s s s s e e m m b b l l y y
The deadweight valve and solenoid exhausts are directed into a condensation box,
located in the rear of the fryer. Should this box become clogged, water would spew
from the top of the box. The box can be cleaned by running a wire or long brush from
the top of the box, through the hole in bottom of the box, or the bottom of the box can
be removed to clean.
When cleaning the vat (frypot), pour a cup of cleaning solution
into the large exhaust hose at the top of the exhaust tank. This
NOTICE:
helps prevent the box from getting clogged.