• For fryers with standard thermostat part number 14293, continuity check shall
be made between terminal 52 on thermostat and wire nut between drain
switch and gas control valve. If the circuit is open, the drain switch is bad and
needs to be replaced.
If the circuit is open, the drain switch is bad and needs to be replaced.
2 2 ) )
To replace the drain switch, remove the two screws and nuts securing the
3 3 ) )
switch and switch cover.
Label and disconnect the wires.
4 4 ) )
Connect the wires to the new drain switch.
5 5 ) )
Position the actuator and attach the drain switch and switch cover with the two
6 6 ) )
screws and nuts.
Secure with the two screws and nuts.
7 7 ) )
Test to see if drain valve extension rod actuates the switch.
8 8 ) )
NOTICE:
2 2 . . 1 1 5 5 . . 3 3 M M a a i i n n P P o o w w e e r r S S w w i i t t c c h h
T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y d d a a m m a a g g e e , , m m o o v v e e t t h h e e
p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r
u u n n p p l l u u g g c c o o r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
The Main Power switch is a three way switch with a center OFF position. With the
switch in POWER position, the fryer will operate. With the switch in the PUMP
position, the filter pump will operate but the heating unit will not.
Listen for audible click of switch while rotating drain valve
extension rod.
39