5.10  Connecting 200-240 VAC Power
AC Power Diagrams
Figure 5-11. Typical AC Power Installation with Single-Phase Supply
Table 5-12. AC Power Installation with Single-Phase Supply Description
Item
1
2
3
4
Figure 5-12. Single-Phase Load across L1 and L2 of a Three-Phase Supply
72
L
1
N
E
Description
Single-phase 200-240 VAC, 20 A
L = Line
N = Neutral
E = Earth Ground
User-supplied, must be slow-blow.
User-supplied AC power cable
eMB-40R Single-phase, 200-240 VAC
L1
L2
1
2
L3
E
Cobra 350 User's Guide
2
F1 10A
3
E
N
L
4
2
5
F5 10 A
F4 10 A
3
E
N
L
4
05624-000 Rev. K