Control- / Status Byte 750-404/000-004 - WAGO 750-404 Manual

Wago-i/o-system 750 fieldbus independent counter modules
Table of Contents

Advertisement

20 •
750-404 [Up/Down Counter /100 kHz]
Process Image

2.1.2.7.3 Control- / Status byte 750-404/000-004

The control byte C0 serves for setting and locking the counter and for setting
the outputs dependent or independently on the counter reading. The status byte
S0 shows the status of the counter and the inputs and outputs.
0
X
With the control and status byte the following tasks are possible:
Set Counter:
Put Bit 5 into the control byte. The counter with the 32 bit value is loaded into
output bytes 0-3. As long as the bits are set, the counter can stop and
information is stored. The ensuing data of the counter will be conveyed to the
status byte.
Lock Counter:
Bit 4 is set into the control byte, then the count process is suppressed. Bit 4 in
the status byte communicates the suppression of the counter.
Switching the outputs dependent of the counter:
The bits 0 and 1 activate the function: output dependent setting of binary
outputs. If the counter reading 0x80000000 is exceeded, output DO 1 is
activated. For the output DO 2 only the bottom 16 bits of the counter reading
are taken into account, which means that output DO 2 is activated as soon as
the counter reading 0x8000 is exceeded. Having reached 0 again, the outputs
are reset.
B7
B6
B5
0
0
Set
counter
This constant must be set to zero.
B7
B6
B5
X
X
Counter
is set
This value is not evaluated.
Control byte
B4
B3
Lock
Set
Counter
output
output
DO 2
Status byte
B4
B3
Counter
actual
actual
is
signal at
signal at
blocked
output
output
DO 2
B2
B1
B0
Set
Output
Output
O2
O1
DO 1
activated
activated
dependin
dependin
g of the
g of the
counter
counter
value
value
B2
B1
B0
actual
actual
signal at
signal at
input
input
DO 1
U/D
CLOCK
WAGO-I/O-SYSTEM 750
I/O Modules