It is important that the owner/operator understands as much as possible during the
training startup of the new equipment. Use the control panel above to explain key
functions and display segments.
Characteristics of the control
•
Ease of use
•
Ability of individual program modification
•
Eight pre-set programs with up to 17 additional programs available
•
Audit of programs usage
•
Temperature control achieved by hot and cold valve operation to within 3-5f
•
Six separate water level settings
•
Program advance feature
•
Delayed start feature
•
Diagnostic "TesT" feature for troubleshooting washer faults
Basic Logi Pro pre-set programs
The preset programs are listed below, these programs can be modified through the
"Advanced" use mode. Consult "Operations Instruction Manual" Cod. 523340 Rev.
10 or later.
Modifying a program
The Logi Pro control has full program capability in all phases with exception of phase 11
which cannot be deactivated, this makes this control unique when compared to the
standard Logi control.
Definition of phases;
PH – phase number Y – phase active, N – phase not active
L – Bath level 1 thru 6 standard L3 wash bath, L5 rinse bath
C/F – Programmed water temperature of phase
1d – chemical injection 0-4, dt – signal time
2d – chemical injection 0-4, dt – signal time
R – Rotation type no, lo-5sec on 25 off, Md-15 on 15off, Hi-25 on 5 off
Rt – phase run time in minutes 0 thru 20
C – Synthetic cool down
Rh – rinse hold
E – drain and speed, 0 thru 6
ET – extract time in minutes 2-9