Chapter 5 MACHINE DISASSEMBLY

5.6.6 LOAD CELL BOARD

Make sure that both front and rear stainless-steel cases are removed. (Refer to section 5.6.4)
1.
Remove the six screws fixing the upper
2.
case.
Remove the three screws fixing the load cell board housing.
4.
* Reverse this procedure for assembly.
5-36
Front case
Rear case
Detach the upper case and unplug the
3.
harness.
Load Cell board
housing
UNI-7 Service Manual