5.3

BAKERY TYPE

5.3.1 UPPER CASE

Pull out the cassette unit from the main unit.
1.
Disengage the two hooks (red) and lift to
3.
remove the top cover.
Make the operation panel angle about 45°
5.
and pull out the hinge cover.
UNI-7 Service Manual
Chapter 5 MACHINE DISASSEMBLY
Remove the two screws located at the rear
2.
side of the top cover.
Top cover
Raise the operation panel and remove the
4.
screw fixing the hinge cover.
Remove the six screws fixing the upper case.
6.