1 System Basic Configuration
1.4.3 Operation Panel I/O Unit
FCU8-DX830/FCU8-DX837/FCU8-DX730 (M800W/M80W)
[LED]
FCU8-DX830/FCU8-DX837
(1)
(2)
(3)
(4)
No.
Name
(1)
FUSE
Fuse status
(2)
DOCOM
Energization status of DC24V input
(DOCOM) of CG32/CG34 connector
(3)
EMG
Emergency stop input status
(4)
24VDCIN Energization status of 24VDC input of
DCIN connector
(5)
5VIN
5V power supply circuit status
(6)
3VIN
3.3V power supply circuit status
(7)
12VON
12V power supply circuit status
(8)
ALM1
RIO communication error
(9)
ALM2
RIO communication error
(10) ALM3
RIO communication error
(11) ALM4
RIO communication error
IB-1501273-F
(7)
(5)
(6)
(10)
(8)
(9)
(11)
Function
Color
Green
Green
Red
Green
Green
Green
Green
Red
Red
Red
Red
22
FCU8-DX730
(1)
(2)
State
Normal At fault
Lit
Not lit
Not lit when a fuse has been
blown out.
Lit
Not lit
Lit when a current is applied.
Not lit
Lit
Lit when an emergency stop
has occurred.
Lit
Not lit
Lit when a current is applied.
Lit
Not lit
Lit when the circuit is normally
operated.
Lit
Not lit
Lit when the circuit is normally
operated.
Lit
Not lit
Lit when the circuit is normally
operated.
Not lit
Lit
Lit when RIO communication
error has occurred.
Not lit
Lit
Lit when RIO communication
error has occurred.
Not lit
Lit
Lit when RIO communication
error has occurred.
Not lit
Lit
Lit when RIO communication
error has occurred.
(7)
(5)
(6)
(8)
(9)
Supplement