MITSUBISHI CNC
2 General Specifications

2.5 Operation Panel I/O Unit

Characteristics of operation panel I/O unit are as follows.
(1) Number of DI/DO points that can be mounted on the machine operation panel is 64/64 as standard and 96/96 at the
maximum. Both sink and source types are available.
Operation panel I/O unit DI/DO uses equivalent serial link connections as those used for remote I/O.
(2) Remote I/O interface --- 1ch
Remote I/O unit, scan I/O card, etc. can be extended up to 4 stations.
(a) When FCU7-DX710/711 are used: Up to 4 stations, 128 points/128 points in total, are available.
(b) When FCU7-DX720/721/730/731 are used: Up to 3 stations, 96 points/96 points in total, are available.
(Note)
The maximum number of stations that can be extended is described above whether DI/DO of the
operation panel I/O unit is used or not.
(3) Manual pulse generator --- 2ch
5V and 12V manual pulse generators can be connected.
(4) Installation on the back side of the keyboard unit is possible. Allows space saving inside the operation panel.
Classification
DI 24V/0V common input
DO Sink output
DI 24V/0V common input
DO Sink output
AO Analog output
DI 24V/0V common input
DO Sink output
DI 24V/0V common input
DO Source output
DI 24V/0V common input
DO Source output
AO Analog output
DI 24V/0V common input
DO Source output
(Note 1) The station Nos. occupied by the operation panel I/O unit cannot be changed. If the unit has rotary switches,
do not change the switch settings when shipped.
(Settings when shipped: CS1 -> 0/ CS2 -> 1/ CS3 -> 6)
(Note 2) Set the number of DI points that are simultaneously turned ON to be less than half of the total points. If many
points are set to be simultaneously turned ON in high temperature, operation panel I/O unit may be
deteriorated due to the heat.
36
Type
Base card
FCU7-DX710
Terminator (R-TM)
Base card
FCU7-DX720
Terminator (R-TM)
Add-on card
Base card
FCU7-DX730
Terminator (R-TM)
Add-on card
Base card
FCU7-DX711
Terminator (R-TM)
Base card
FCU7-DX721
Terminator (R-TM)
Add-on card
Base card
FCU7-DX731
Terminator (R-TM)
Add-on card
Components
DI: 64-points 24V/0V common type
DO: 64-points sink type
MPG:2ch
Occupied stations (fixed): 1, 2, 7, 8
RIO3 extensible stations: 3, 4, 5, 6
DI: 96-points 24V/0V common type
DO: 80-points sink type
MPG:2ch
AO: 1 point
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI: 96-points 24V/0V common type
DO: 96-points sink type
MPG: 2ch
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI: 64-points 24V/0V common type
DO: 64-points source type
MPG:2ch
Occupied stations (fixed): 1, 2, 7, 8
RIO3 extensible stations: 3, 4, 5, 6
DI: 96-points 24V/0V common type
DO: 80-points source type
MPG:2ch
AO: 1 point
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI: 96-points 24V/0V common type
DO: 96-points source type
MPG:2ch
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
Remarks