General Connection Diagram [M80W] - Mitsubishi Electric M80 Series Maintenance Manual

Hide thumbs Also See for M80 Series:
Table of Contents

Advertisement

M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration

1.2.2 General Connection Diagram [M80W]

Windows-based display (15-type)
Dotted lines indicate the sections prepared by the machine tool builder.
<> Angle brackets indicates attached cable of unit.
L1 L2 L3
No-fuse breaker
(NFB)
ON
OFF
MC
MC
MC
24VDC stabilized
power supply
DCOUT
ACIN
FG
CP
(Note 1)
Drive units
Handy terminal
G430
(Note 1) For information on how to connect the drive unit, refer to the drive unit's manual.
(Note 2) When using a keyboard unit, install the operation panel I/O unit on the back of the keyboard unit.
Note
(1) For the connection of MITSUBISHI CNC machine operation panel, refer to "M800W/M80W Series Connection and Set-
up Manual".
(2) When the handle of handy terminal is used, connect ENC connector of G430 cable to MPG connector of the operation
panel I/O unit.
Because the pin assignment of ENC connector of G430 is different from that of MPG connector of the operation panel
I/O unit, conversion is required.
The conversion cable needs to be prepared by the MTB.
Personal computer unit
FCU8-PC231
ON
G170
ON/OFF
OFF
CFast unit
CFast
CFAST
FCU8-CF001-001
Stored in
personal computer unit
J303
Network
LAN
J303
GDI
J291
KEYUSB
J070/071
DCIN
24VDC
24VDC
Operation panel I/O unit
FCU8-DX830/837
FG
KEYUSB
DX830:
CJ71
No safety signal input
DX837:
With safety signal input
Safety signal input
SDI
(Safety signal input is
Max. 8 points
DX837 only.)
J210
RIO3
J070/071
DCIN
24VDC
Control unit
FCU8-MU044
RIO3
GDI
J303
Network
LAN
J395/J396
OPTH1
J395/J396
OPTH2
Skip signal input
J100
SKIP
Max. 8 points
RS232C
1ch:J030
device
2ch:J031
2ch
SIO
Emergency
J120
EMG
stop switch
J070/071
DCIN
24VDC
SD 
memory 
SD
SD
card
BTBOX
Added onto back of
Display unit
display unit
FCU8-DU181-36
<J09x>
LVDS1
LVDS2
15-type LCD
<J190>
<J081>
INV
with touch panel
Backlight
<J290>
I/F PCB
<J420>
USB2-1
<J292>
USB2-2
MENUKEY
USB2-3
USB-RS232C
USB2-4
conversion
USB2-5
USB2-6
USB3-1
USB3-2
Keyboard unit
FCU8-KB04x/KB083
(Note 2)
<G402>
NCKB
5V:J023/J024/J025
12V:J020/J021/J022
MPG
J350/351
CG31
J350/351
CG32
J350/351
CG33
Machine operation
panel made by the
J350/351
CG34
machine tool builder
J120
EMG
Remote I/O unit
24VDC
J350/351
DI:CJ31/33
DCIN
J350/351
DO:CJ32/34
RIO3EXT
J210
RIO1
RIO2
FCU8-DX2xx/DX6xx/DX4xx
MITSUBISHI CNC Machine Operation Panel
FCU8-KB92x
J210
24VDC
Remote I/O unit
24VDC
24VDC
DCIN
DI:CJ31/33
J070/071
J070/071
DO:CJ32/34
J210
RIO1
RIO1
RIO2
Remote I/O unit
24VDC
24VDC
DCIN
DI:CJ31/33
J070/071
DO:CJ32/34
J070/071
J210
RIO2
RIO1
RIO2
FCU8-DX2xx/DX6xx /DX4xx
Max. 32 units for each port
RIO4/M
Stored in control unit
Function
expansion unit
EXT1
FCU8-EX54x
Communication
expansion unit
EXT3
FCU8-EX56x
7
SD 
memory 
SD
SD
card
USB
USB
USB memory
Menu key
RS232C
device
Manual pulse
generator (5V/12V)
24VDC
Emergency
stop switch
Machine
control
relay/contact
To the next remote I/O
or terminator connector
(R2-TM)
FCU8-KB941/KB931
<G460>
Remote I/O unit
J350/351
Machine
control
DCIN
DI:CJ31/33
J350/351
relay/contact
DO:CJ32/34
To the next
RIO1
RIO2
remote I/O or
terminator
connector
(R2-TM)
Remote I/O unit
Machine
J350/351
control
DCIN
DI:CJ31/33
J350/351
relay/contact
DO:CJ32/34
RIO1
RIO2
To the next
remote I/O or
terminator
connector
(R2-TM)
Energy measuring units
(EcoMonitor)
IB-1501273-F

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents