Mitsubishi Electric M80 Series Maintenance Manual page 149

Hide thumbs Also See for M80 Series:
Table of Contents

Advertisement

M800/M80/E80 Series Maintenance Manual
4 Failure Diagnosis
(1)  
(2)  
Display items
Display items
(1)
State
History data
Sampling data
(2)
Sampling specifications Specify the part system, spindle, and servo axes where sampling data is to be collect-
System
Spindle
Servo
(3)
Collecting data select
Key history
Alarm history
PLC I/O history
AC alarm history
Touch history
Tool ofs change
Workpiece ofs change This selects whether or not workpiece offset change history data is collected.
IB-1501273-F
Display the history data and sampling data collection status.
Display the history data collection status.
History collecting: History data collection is in progress.
History stop: History data collection is stopped.
Display the sampling data collection status.
Sampling: Sampling data collection is in progress.
Sampling stop: Sampling data collection is stopped.
Sampling invalid: Sampling data collection is disabled.
ed.
Specify the part systems where sampling data is not to be collected.
Specify the part system in HEX.
When "0" is set, sampling is carried out for all part systems.
This setting is ignored if a non-existent part system is specified.
Specify the spindle where sampling data is not to be collected.
Specify the part system in HEX.
When "0" is set, sampling is carried out for all spindles.
This setting is ignored if a non-existent spindle is specified.
Specify the servo axes where sampling data is not to be collected.
Specify the part system in HEX.
This setting is not system-specific.
When "0" is set, sampling is carried out for all axes.
This setting is ignored if a non-existent servo axis is specified.
This selects the diagnosis data to be collected.
0: Collected.
1: Not collected.
This selects whether or not key history data is collected.
This selects whether or not alarm history data is collected.
This selects whether or not PLC input/output signal history data is collected.
This selects whether or not AC power ON/OFF history data is collected.
This selects whether or not touchscreen history data is collected.
This selects whether or not tool offset change history data is collected.
122
Details
(3)

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents