Mitsubishi Electric M80 Series Maintenance Manual page 53

Hide thumbs Also See for M80 Series:
Table of Contents

Advertisement

M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration
[LED: FCU8-DX651]
No.
Name
(1)
H1
Safety relay output SYR00 status
H2
Safety relay output SYR01 status
H3
Safety relay output SYR02 status
H4
Safety relay output SYR03 status
(2)
ALM
RIO communication error
(3)
DCIN
Energization status of 24VDC input of
DCIN connector
(4)
FUSE
Fuse status
IB-1501273-F
(2)
(1)
Function
Color
Green
Green
Green
Green
Red
Green
Green
26
(3)
(4)
State
Normal
At fault
Lit
Not lit
Not lit when a relay has been
blown out.
Lit
Not lit
Not lit when a relay has been
blown out.
Lit
Not lit
Not lit when a relay has been
blown out.
Lit
Not lit
Not lit when a relay has been
blown out.
Not lit
Lit
Lit when RIO communication
error has occurred.
Lit
Not lit
Lit when a current is applied.
Lit
Not lit
Not lit when a fuse has been
blown out.
Supplement

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents