M800/M80/E80 Series Maintenance Manual
4 Failure Diagnosis
Display items
(3)
NC-I/O safety communica-
tion
Menus
Menus
This switches the screen to the configuration diagnosis display of the smart safety observation.
Config
diag
This switches the screen to the signal monitor display of the smart safety observation.
Signal
monitor
This switches the screen to the drive monitor display of the smart safety observation.
Drive
monitor
This switches the screen to the version display of the smart safety observation.
Version
This switches the drive monitor diagnosis information to the servo unit information.
Servo
Only when the drive monitor is displayed, the menu appears, and the operation can be performed.
unit
This switches the drive monitor diagnosis information to the spindle unit information.
Spindle
Only when the drive monitor is displayed, the menu appears, and the operation can be performed.
unit
This switches the axis to be displayed on the drive monitor.
Next
Only when the number of axes is five or more on the drive monitor screen, the menu appears, and the
axis
operation can be performed.
This displays the communication status of the safety I/O communication.
To perform the safety I/O communication, at least one of remote I/O channels
needs to be configured with the safety I/O devices (safety remote I/O unit, opera-
tion panel equipped with safety I/Os) and RIO2.0 unit alone.
Writing safety PLC:
This displays the status (Done/Not yet) whether the PLC ladder for safety is written.
Safety I/O comm:
"OK" is displayed when the channel is configured only with RIO2.0 units.
Safety I/O connect:
"Yes" is displayed when connected to the safety I/O devices (safety RIO unit, op-
eration panel equipped with safety I/O).
Details
111
Details
IB-1501273-F