4 Failure Diagnosis
Menus
Menus
This erases the information in the line where the cursor is. (One entire line becomes blank.) The cursor
Line
does not move at this time.
clear
The contents of the set address data (Part system No, Section/sub-section/axis) for all the lines are con-
Data
stantly displayed.
read
The Index No. highlight (indicating data is being set) is released.
The cursor appears in "Part system No" of that line.
This writes the data in the setting area to the NC memory indicated by address data at the cursor posi-
Data
tion. (*1)
write
The Data No. highlight (indicating data is being set) is released, and constant display is started.
After writing, the cursor moves to "Part system No" of the next line.
Based on the data of the address data where the cursor is, this displays the continuous data to which
Subsect
the sub-section No. has been added to the address data from the line where the cursor is.
continu
The cursor moves to "Part system No " of that line.
Based on the data of the address data where the cursor is, this displays the continuous data to which
Axis
the axis No. has been added to the address data from the line where the cursor is.
continu
The cursor moves to "Part system No " of that line.
(*1) Decimal, hexadecimal, floating point data and character string data writing is possible. Note that hexadecimal, floating
point data and character strings may not be settable depending on the data.
Decimal: Integers without decimal points (Example) -1234
Hexadecimal: An "H" is necessary at the end (Example) 1234H
Floating point data: Data with a decimal point (Example) -12.3
Character string data: Character string (Example) X