Commissioning
• Several parameters have to be set before the motor can be started up. The values can be found in
section "Configuration of the main parameters [} 92]".
Please set these parameters before continuing with the motor commissioning procedure.
Adding an axis manually
• First add a new task. Right-click on NC configuration and select "Append Task..." (see Fig. Adding a
new task).
• Rename the task if required and confirm with OK.
Fig. 101: Adding a new task
• Right-click on Axes, then add a new axis (see Fig. Adding a new axis).
Fig. 102: Adding a new axis
• Select Continuous Axis type and confirm with OK (see Fig. Selecting and confirming the axis type).