Beckhoff EL72 1 Series Documentation page 151

Servo motor terminal, 50 vdc
Table of Contents

Advertisement

Index 1C33 SM input parameter
Index (hex) Name
1C33:0
SM input parameter
1C33:01
Sync mode
1C33:02
Cycle time
1C33:03
Shift time
1C33:04
Sync modes supported Supported synchronization modes:
1C33:05
Minimum cycle time
1C33:06
Calc and copy time
1C33:07
Minimum delay time
1C33:08
Command
1C33:09
Maximum delay time
1C33:0B
SM event missed
counter
1C33:0C
Cycle exceeded
counter
1C33:0D
Shift too short counter as 0x1C32:13 [} 150]
1C33:20
Sync error
Index F000 Modular device profile
Index (hex) Name
F000:0
Modular device profile General information for the modular device profile
F000:01
Module index distance Index spacing of the objects of the individual channels UINT16
F000:02
Maximum number of
modules
Index F008 Code word
Index (hex) Name
F008:0
Code word
Index F010 Module list
Index (hex) Name
F010:0
Module list
F010:01
SubIndex 001
F010:02
SubIndex 002
EL72x1
EL72x1-0000 (MDP742) - Object description and parameterization
Meaning
Synchronization parameters for the inputs
Current synchronization mode:
• 3: DC - Synchronous with SYNC1 Event
as 0x1C32:02 [} 150]
Time between SYNC0 event and reading of the inputs
(in ns, only DC mode)
• Bit 0: free run is supported
• Bit 1: synchronous with SM 2 event is
supported (outputs available)
• Bit 1: synchronous with SM 3 event is
supported (no outputs available)
• Bit 2-3 = 01: DC mode is supported
• Bit 4-5 = 01: input shift through local event
(outputs available)
• Bit 4-5 = 10: input shift with SYNC1 event (no
outputs available)
• Bit 14 = 1: dynamic times (measurement
through writing of 0x1C32:08 [} 150] or
0x1C33:08 [} 151])
as 0x1C32:05 [} 150]
Time between reading of the inputs and availability of
the inputs for the master (in ns, only DC mode)
as 0x1C32:08 [} 150]
Time between SYNC1 event and reading of the inputs
(in ns, only DC mode)
as 0x1C32:11 [} 150]
as 0x1C32:12 [} 150]
as 0x1C32:32 [} 150]
Meaning
Number of channels
Meaning
see note [} 25]!
Meaning
Maximum subindex
Encoder profile number
Servo drive profile number
Version: 3.3
Data type
Flags
Default
UINT8
RO
0x20 (32
UINT16
RW
0x0000 (0
UINT32
RW
0x0003D090
(250000
UINT32
RO
0x00001C52
(7250
UINT16
RO
0xC007
(49159
UINT32
RO
0x0001E848
(125000
UINT32
RO
0x00000000
(0
dec
UINT322
RO
0x00001C52
(7250
UINT16
RW
0x0000 (0
UINT32
RO
0x00001C52
(7250
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
BOOLEAN
ROO
0x00 (0
Data type
Flags
Default
UINT8
RO
0x02 (2
RO
0x0010 (16
UINT16
RO
0x0002 (2
Data type
Flags
Default
UINT32
RW
0x00000000
(0
dec
Data type
Flags
Default
UINT8
RW
0x02 (2
UINT32
RW
0x00000201
(513
UINT32
RW
0x000002E6
(742
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
)
dec
)
dec
)
dec
151

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

El7211-0000El7201-0000El7201-0001El7211-0001

Table of Contents