13
Troubleshooting Tables
PROBLEM
PROBABLE CAUSE
1.
2. Upper torque spring not connected.
Product too
thin.
3. Adjustment screw not properly set.
4. Component failure.
1.
2. Adjustment screw not properly set.
Product too
thick.
3. Lower torque spring not connected.
4. Component failure.
Leakage of
1.
product from
drain tube.
2. Beater shaft assembly damaged.
1. Head quad ring defective.
2. Hand knobs not drawn up properly.
Product
leaking around
head.
3.
4. Damaged head assembly.
44
Models 876, 876B, 876C, 876RH, 876BRH, 876CRH & 875 Batch
Improper mixing of product. Brix too
high.
Improper mixing of product. Brix too
low.
Cup seal leaking or improperly
installed.
Damaged or worn o-ring on the
plunger assembly.
(continued)
REMEDY
Follow mixing instructions on
1.
product label. See section 10.2,
Adjusting Product Consistency.
Install torque spring. See
2.
Section 10.2, Adjusting Product
Consistency.
Adjust screw to proper consistency
3.
of product. See section 10.2,
Adjusting Product Consistency.
Contact your Electro Freeze
4.
Distributor for service.
Follow mixing instructions on
1.
product label. See Section 10.1,
Determining Product Consistency.
Adjust screw for proper consistency.
2.
See Section 10.2, Adjusting Product
Consistency.
Install torque spring. See Section
3.
10.2, Adjusting Product Consistency.
Contact your Electro Freeze
4.
Distributor for service.
Replace cup seal or install
1.
properly.
Contact your Electro Freeze
2.
Distributor for service
1. Replace quad ring.
Tighten hand knobs (hand tighten
2.
only).
Replace and lubricate o-rings on
3.
plunger assembly.
Contact your Electro Freeze
4.
Distributor for service
184633