10

Slush Product Information

10.1

Determining Product Consistency

1. For slush mix, use a clear, straight-
sided glass of any size and draw off
a full glass of frozen product (slush
flavor bottles work well).
2. Allow the glass to stand for 2 minutes
at room temperature away from any
heat source.
10.2

Adjusting Product Consistency

Product consistency has been preset
at the factory. Further adjustment
may be necessary to obtain your
desired consistency. To adjust product
consistency, proceed with the following
steps:
1. Allow the freezer to operate
until the compressor shuts off.
Dispense sufficient product to check
consistency. (Refer to Section 10.1,
Determining Product Consistency.)
2. Find the small adjustment cover
toward the rear in the center of the left
Figure 10-1 Attach Springs to Beater
184633
Models 876, 876B, 876C, 876RH, 876BRH, 876CRH & 875 Batch
3. Verify the product consistency by
determining the amount of liquid at
the bottom of the glass.
Examples of settings :
5% liquid
1% liquid
(Starts to stack)
0% liquid
(Stacks well)
CAUTION
To prevent bacteria growth,
use only approved sanitizers to
sanitize the machine. Sanitizing
must be done just prior to
starting the machine. Failure
to do so could create a health
hazard.
side panel.
3. Remove the top screw holding the
cover and loosen the bottom, letting
the cover swing away from the access
hole.
4. Look into the access hole and you will
see an arm extending from the drive
motor (see figure 10-1.) The arm is
held in place by springs on both the
top and bottom. At the end of this
arm is a nylon (product) adjusting
stud. This stud is the only operating
adjustment on the freezer.
5. If the product is too thin, turn the
adjusting screw counterclockwise
(up) ½ turn. If the product is too thick,
turn the adjusting screw clockwise
(down) ½ turn. Close cover and
reconnect power. Turn selector
switch to "FREEZE" and wait until the
compressor has cycled off.
6. Recheck the product consistency
in 30 minutes. Repeat steps and
recheck until proper consistency is
obtained. Close cover.
For further information contact your
local Electro Freeze Distributor or the
Service Department of H. C. Duke &
Son, Inc. (309) 755-4553 or (800) 755-
4545.