160
2.
Connect the valve (4) to the hose (5) for the suction container.
3.
Connect the connection hose (6) for the compressed air to
the valve (4).
7.13.2 Adjusting the operating pressure
NOTICE
Property damage from incorrect adjustment!
Incorrect operating pressure can result in damage to the
machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
Proper setting
Refer to the Technical data ( p. 187) chapter for the permissi-
ble operating pressure. The operating pressure cannot deviate by
more than ± 0.5 bar.
Fig. 104: Adjusting the operating pressure
①
(1) - Pressure regulator
To adjust the operating pressure:
1.
Pull the pressure regulator (1) up.
(2) - Pressure gage
Operating Instructions 581 - 02.0 - 05/2019
Setup
②