Chapter 6   Troubleshooting
Bit Set
You may be exceeding the receiver's velocity limit. If so, reduce velocity. This error can
21
only be cleared by resetting the receiver.
22
Reload firmware using WinLoad or the SoftLoad commands.
23-30
Reserved
31
Possible hardware failure. Contact Customer Support on page 9.
Table 11: Resolving an Error in the Receiver Status Word
Bit Set
Check the Error Word in the RXSTATUS log. See also Table 10: Resolving a Receiver
0
Error Word on the previous page
Check the temperature ranges in
1
SMART2 Environmental and Electrical Specifications on page 70
l
2
See
3
4
5
6
Check the CPU idle time. Check for unnecessary logging. Check for simultaneous use of
7
functionality.
See Table 7: Serial Ports Supported on page 22
8
Also, check the Auxiliary 2 Status word to determine which COM port has overrun its
buffer.
9-11
Reserved
15
Check the Auxiliary 1 status word to determine which RF channels are jammed.
16-17
Reserved
When the receiver has tracked GNSS satellites long enough for a valid almanac to be
18
received, this bit will be set to 0.
19
None. This bit only indicates if the receiver has calculated a position.
None. This bit is a status bit indicating if the receiver's position has been manually fixed
20
and does not represent a problem. Refer also to the FIX command.
None. This bit indicates if clock steering has been manually disabled. Refer also to the
21
FRESET command.