Safety - Danfoss VLT HVAC Drive FC 100 Series Design Manual

Hide thumbs Also See for VLT HVAC Drive FC 100 Series:
Table of Contents

Advertisement

®
VLT
HVAC Drive Design Guide
3.
Choose "Open"– stored files will be shown
4.
Open the appropriate file
5.
Choose "Write to drive"
All parameter settings are now transferred to the frequency converter.
A separate manual for PC-based Configuration Tool MCT 10 is available.
MCT 31
The MCT 31 harmonic calculation PC tool enables easy estimation of the
harmonic distortion in a given application. Both the harmonic distortion
of Danfoss frequency converters as well as non-Danfoss frequency con-
verters with different additional harmonic reduction devices, such as
Danfoss AHF filters and 12-18-pulse rectifiers, can be calculated.
MCT 31 can also be downloaded from the Danfoss Internet:
+Program.htm
.

5.6. Safety

5.6.1. High Voltage Test
Carry out a high voltage test by short-circuiting terminals U, V, W, L
and the chassis.
NB!
When running high voltage tests of the entire installation, interrupt the mains and motor connection if the leakage currents are too
high.
5.6.2. Safety Earth Connection
The frequency converter has a high leakage current and must be earthed appropriately for safety reasons acording to EN 50178.
The earth leakage current from the frequency converter exceeds 3.5 mA. To ensure a good mechanical connection from the earth
cable to the earth connection (terminal 95), the cable cross-section must be at least 10 mm2 or 2 rated earth wires terminated sepa-
rately.
The PC-based Configuration Tool MCT 10 modules
The following modules are included in the software package:
Ordering number:
Please order your CD containing the PC-based Configuration Tool MCT 10
using code number 130B1000.
MCT 10 can also be downloaded from the Danfoss Internet:
www.danfoss.com/BusinessAreas/DrivesSolutions/Softwaredownload/
DDPC+Software+Program.htm
Ordering number:
Please order your CD containing the MCT 31 PC tool using code number
130B1031.
http://www.danfoss.com/BusinessAreas/DrivesSolutions/Softwaredownload/DDPC+Software
, L
and L
. Energize by max. 2.15 kV DC for one second between this short-circuit
1
2
3
MG.11.B7.02 - VLT
®
is a registered Danfoss trademark
5. How to Install
MCT 10 Set-up Software
Setting parameters
Copy to and from frequency converters
Documentation and print out of parameter settings
incl. diagrams
Ext. User Interface
Preventive Maintenance Schedule
Clock settings
Timed Action Programming
Smart Logic Controller Set-up
.
5