Description of the defect: the control unit detects a failure in the ABS valves relay or lack of power supply
in pin 3 of the control unit. Checks: check pin 3 of the ABS control unit connector, the 25 A fuse continuity
and the relative wiring (red/white). Solution: restore the ABS control unit connector or the 25 A fuse or
the wiring.
If functioning is correct, proceed to the next check
Checks: no control is possible. Solution: replace ABS control unit.
CONTROL UNIT AXONE ERROR
Description of the defect: control unit failure. Checks: no control is possible. Solution: replace ABS
control unit.
SUPPLY VOLTAGE AXONE ERROR (operation interval 9.4V - 16.8V)
Error saved only with vehicle speeds over 6 km/h (3.7 m/h).
Description of the defect: the control unit detects a failure in the electric supply voltage. Checks: check
if the voltage is too low (below 9.4V. Solution: charge or replace the battery.
If functioning is correct, proceed to the next check
Checks: check if the voltage is too high (over 16.8V) Solution: replace the voltage regulator
Modulator
Remove the saddle.
Remove the battery.
Disconnect the ABS control unit con-
nector.
Empty the brake fluid stored in the
pipes into a container by disconnecting
the pipes from the pump and the cal-
lipers.
Mark the position of the pipes in order
to avoid possible errors when refitting
them.
Unscrew and remove the two nipples
(1) and the two nipples (2) fixing the
brake pipes to the ABS control unit and
collect the gaskets.