8
Operation and parameter setting on the PC with enSuite

8.4.6 Function "Live data and trending"

With this function EnSuite offers the possibility to view live data of the device shown as numerical
value and graphically . First of all, you need a connection to the device ( See chapter 8.1.2).
After you have gained access to the Q2, you can right-click on the Q2-symbol (on the left hand
side window). In the appearing list (Navigation Window lower part) select the point "Live data and
trending". The parameters are read from the Q2 and then a new tab opens in the middle of the
screen (see figure).
In the window there are 2 tabs „Dynamic chart" and "Live data". In the tab "Live data" you can
monitor many different types of data simultaneously, but you will only see the numerical value. In
the tab "Dynamic Chart" you can monitor just 2 groups of values graphically. Group means: while
there are at most 2 vertical axes possible, there are only two positions to place the unit of the
value. As a consequence, you can place many different types of data here as long as they fall
into no more than two unit categories, i.e. if you already monitor 2 temperatures (in °C) and 1
pressure (in MPa), the possibilities are exhausted.
Examples of application
Tab "Live data"
On the right side there is a window showing all the values available in the device in a parameter
tree. You simply navigate to the value you want and click and drag the value to the middle
window (see following image detail).
Page 114 of 135