Appendix
Term
Explanation
Checksum
is a method of identification, display and control of the software version. It is calculated by the
Q2 itself. More Information about this enCore device used control method can be found in the
instructions "enCore FC1 - Basic System with SFBs"
DBB Technology
is a valve sealing technology for gas flows. Through a series circuit of two solenoid valves with
a vent between them, the mixing or contamination of gases is prevented even when there are
leaks in the valves.
Display
is the collective term for all representations and views on the device screen
enCore
(Abbreviated as: enCore FC) Summary of different device types used as process computers.
Flow Computer
These include, for example, the enCore ZM1 status converter, the enCore MC1 monitoring and
monitoring unit and the enCore FC1 flow computer. GasLab Q2 also uses this software basis
for data management..
Error List
helps the user to identify errors and reconstruct the history of the disturbance gradient.
Messages are entered with the comings and goings in the error list, and recorded in the
logbook.
Event
is generated when a measurement violates a user-specified state. The coming of such an
event is logged with time stamp in the error list. These events can't be accepted and disappear
automatically when invalid. All notices will be logged in the logbook.
Export value
The functional blocks of the software make results available, which can be further processed
by other function blocks. These results are called "export values".
Fiscal parameters
are signed with one of these symbols
when SSW is closed. This option is not used when the SSW is open. If you operate the device
with closed SSW parameter with this symbol
this symbol
change will be logged there and therefore monitored.
Gas Quality
are devices that measure the heating value of gases automatically. Calorific value, density at
Analyzers
base conditions and carbon content are determined from the values of the sensors.
Location of use
or of installation is the room or space where the device is present. It must meet the specified
preconditions, the manufacturer, authorities and operators.
Logbook
is a protocol archive that can be used by all software components.
It can record all deviating situations e.g. Errors from the normal measurement mode.
Message
or Signal is an event that is received and processed as a long unsigned integer. It is valid for a
number of evaluation runs of the device. Each time the event changes, the number increases
beginning with 0, whereby the evaluation cycle of occurrence can be detected. This counter
can be reset by a user with the appropriate user rights
Authorizied
A person who has the ability and is authorized, because of his or her technical training,
metrology expert
knowledge and experience, to execute fiscally protected tasks in gas systems within the scope
of legal metrology. A metrology expert is trained to work with fiscally protected devices and
systems, and is acquainted with the relevant standards and regulations that apply in specific
countries.
Operating mode
Operating modes are states that the device can be in use.
Operational
Also called calibration gas, is held in cylinder connected firmly to the Q2 and is part of the
calibration gas
measuring device. It is a mixture of methane-clean gas and carbon dioxide with fiscal
established properties is required for automatic calibration.
Ordinal number
archived data has a serial number (automatically assigned identification number). This is
structured in such a way so that the first archive entry has the number 1 for each subsequent
entry, the number is increased by one.
Process gas
is the gas which has to be analyzed or measured. It is supplied to and through the device in
normal operation and is also called sample gas
is an electrical system in which the voltage can't exceed Extra-Low Voltage under base
Protective Extra
conditions, and under single-fault conditions, except earth faults in other circuits (IEC 61140
Low Voltage (PELV)
defines a PELV system). Please contact the Elster GmbH in if you want to use this system
because a modified wiring is required.
GasLab Q2
can also be changed with a closed SSW; as long as the audit trail is not full, the
G a s Q u a l i t y A n a l y z e r
to give information about the change opportunities
, changes could not be made. Parameters with
Page 127 of 135
11