10.4 CLEANING THE PARTS AFTER DISASSEMBLY

WARNING
Incompatibility of cleaning agent and working medium!
Risk of explosion and danger of poisoning by toxic gases.
Examine the compatibility of the cleaning agents and working media on the basis
of the safety data sheets.
Please note:
Thoroughly clean all reusable parts with a suitable cleaning agent.
All dismantled parts have to be clean and dry after cleaning. Care should be taken
that these parts remain free of solvents, grease or sweat from the hands (salt water).
Perform cleaning and mounting tasks wearing gloves.

10.5 ASSEMBLY OF THE DEVICE

In Chapter
14
the order numbers for device spare parts can be found, as well as for wearing
parts such as seals.
Defective parts, O-rings and seal sets must always be replaced.
Use greases and glues in accordance with Chapter 14.
Observe torque specifications in Chapter 14.
Assembly Aids
Order no.
Quantity
1 pc ≙ 50 ml
9992590
1 pc ≙ 50 ml
9992511
1 pc ≙ 150 g
9992528
1 pc ≙ 50 ml
9992831
1 pc ≙ 18 kg!
9998808
1 pc ≙ 1 kg can
9992616
1 pc ≙ 250 ml
322912
Brand notice
The brands specified in this document are property of the respective owners. Loctite , for example, is a
registered brand of Henkel.
ORDER NUMBER DOC 2349980
Designation
Loctite 222
Loctite 243
Loctite 270
Loctite 542
Mobilux EP 2 grease
Molykote DX grease
Hydraulic oil - Wagner
Cobra 40-10 / 2K
Smaller tanks
400 g tube ≙ Order no. 2355418
50 g tube ≙ Order no. 2355419