VERSION 04/2018
OPERATING MANUAL
8.2.8.3 VENT
B_05072
Procedure
1. The dismounted pump is to be place upside down on a suitable underlay and
positioned horizontally. Remove the threaded plug (5).
2. Slowly start up the pump (vent), until no more air bubbles rise from the oil suction
tube.
3. Oil level A in the oil tank has to be within the specified markings X.
4. Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
5. Mount piston cover (1) and hood with casing.
6. Return pump to correct setup position.
7. Pump is ready for use again.
ORDER NUMBER DOC 2349980
5
Cobra 40-10 / 2K
A
5
B_04243
1
45