VERSION 04/2018
OPERATING MANUAL
8.2.8.1 DRAINING OIL
Procedure
1. Decommission and clean
2. Dismount the pump and place it upside down on a suitable underlay and position it
horizontally.
3. Unscrew piston cover (1).
4. Place oil collector (2) under the oil tank.
5. Unscrew oil tank (3) and drain contents.
6. Unscrew and remove locking screws (4) and seals.
7. Slowly start up the pump until no more oil flows out of the oil suction tube.
8. Screw in clean oil tank (3) together with seal.
ORDER NUMBER DOC 2349980
B_05067
Chapter
8.1.2
points 1 to 7.
Cobra 40-10 / 2K
B_05070
2
4
1
3
43