VERSION 04/2018
OPERATING MANUAL
8.2.3.1 PRODUCT HOSES, PIPES AND COUPLINGS
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental influences even when handled correctly.
Check hoses, pipes, and couplings every day and replace if necessary.
Before every commissioning, check all connections for leaks.
Additionally, the operator must regularly check the complete hoses for wear and
tear as well as for damage at intervals that he/she has set. Records of these checks
must be kept.
The complete hose is to be replaced as soon as one of the two following intervals
has been exceeded:
−6 years from the date of the hose crimping (see fitting embossing).
−10 years from the date of the hose imprinting.
Fitting embossing
xxx bar
yymm
XX
Hose imprinting
Wagner
yymm
xxx bar (xx MPa)
e.g., 270 bar (27 MPa)
XX
DNxx (e.g., DN10)
8.2.3.2 CONDENSATE DRAIN FROM THE AIRCOAT FILTER REGULATOR
Frequently drain the condensate that may accumulate in the air filter.
– Make sure the water level in the filter cup never reaches the max. level marked on
the cup itself.
ORDER NUMBER DOC 2349980
Meaning
Pressure
Crimping date (year/month)
Internal code
Meaning
Name / Manufacturer
Date of manufacture (year/month)
Pressure
Internal code
Nominal diameter
Cobra 40-10 / 2K